Call Us
Call Us
08045478451
Ring And Ball Apparatus
Ring And Ball Apparatus

Ring And Ball Apparatus

Price 650 INR/ Piece

MOQ : 2 Pieces

Ring And Ball Apparatus Specification

  • Feature
  • Manual operation, precise temperature control, corrosion-resistant construction
  • Automation Grade
  • Manual
  • Frequency
  • 50 Hz
  • Temperature Range
  • 30C to 110C
  • Voltage
  • 220240V AC
  • Accuracy
  • 1C (temperature) as per IS: 1205/ASTM D36
  • Model No
  • RBA-1205
  • Core Components
  • Ring holder assembly, ball centering guides, bath glass beaker, thermometer clip
  • Capacity
  • 2 samples per test (standard)
  • Power Source
  • Electric heating with 230V AC supply
  • Measurement Range
  • Softening range of 30C to 110C
  • Equipment Materials
  • Copper/brass rings, steel balls, heat resistant test beaker, Bakelite/Fiber frame
  • Type
  • Bench-top laboratory apparatus
  • Usage
  • Determining the softening point of bituminous materials
  • Display Type
  • Analog dial with pointer
  • Dimension (L*W*H)
  • Approx. 250 x 120 x 240 mm
  • Weight
  • Approx. 2.53 kg (assembled)
 

Ring And Ball Apparatus Trade Information

  • Minimum Order Quantity
  • 2 Pieces
  • Main Export Market(s)
  • Australia, South America, Western Europe, Africa, Middle East, Asia, Central America, Eastern Europe, North America
 

About Ring And Ball Apparatus



Our Ring and Ball Apparatus RBA-1205 is a hot-selling, pivotal tool engineered with unbeatable precision for determining the softening point of bitumen, asphalt, and petroleum derivatives. Featuring two copper/brass rings, two nickel-plated steel balls, and a heat-resistant 600 ml glass beaker, it ensures safe and accurate testing in a bench-top design. The built-in adjustable electric heater and the analog dial display offer manual yet reliable temperature regulation. With corrosion-resistant, powder-coated construction and exceptional accuracy (1C), this apparatus delivers dependable results for researchers and industry professionals at a competitive pricing advantage.

Distinct Features, Applications & Advantages

The Ring and Ball Apparatus boasts uncommon durability, thanks to its powder-coated frame and precision-molded ball guide. Typically used to measure the softening point of bituminous substances, it is vital for quality assessment in both laboratory and industrial settings. Its manual temperature regulation allows for precise control during testing, directly contributing to unfaltering accuracy. The apparatus is designed for ease of use, rapid sample handling, and enhanced service lifemaking it a pivotal choice for quality assurance professionals.


Sample Dispatch, Domestic Market & Packaging Assurance

Shipped goods from our facility are carefully packaged to ensure safe and intact delivery, with each unit handover completed after meticulous quality checks. Samples are available upon request, and we primarily serve the main domestic market across India. Our secure shipping process is tailored to safeguard the apparatus during transit, with every component encased in robust packaging for optimal protection.


FAQs of Ring And Ball Apparatus:


Q: How does the Ring and Ball Apparatus determine the softening point of bituminous materials?

A: This apparatus heats two samples simultaneously in a controlled environment using its built-in electric heater. As the temperature increases, the steel balls press down on the rings filled with bituminous material. The softening point is determined when the material allows the ball to drop a specified distance, as monitored on the analog dial.

Q: What are the main advantages of using this apparatus compared to alternatives?

A: The main advantages include competitive pricing, precise manual temperature control, reliable accuracy (1C), and enhanced durability due to its corrosion-resistant, powder-coated frame. Its bench-top design and robust construction make it an ideal choice for laboratories seeking consistent and repeatable results.

Q: When should the apparatus be used in asphalt or bitumen testing?

A: It should be used whenever the softening point or temperature sensitivity of bituminous materials is criticalparticularly for quality control, research, and material specification compliance in road construction and petroleum product laboratories.

Q: Where can the apparatus be installed and operated safely?

A: The bench-top design enables safe installation in most laboratory environments with access to a 220240V AC power supply. Ensure placement on a stable, level surface with adequate ventilation during operation for optimal safety and performance.

Q: What items and accessories are included in the standard apparatus package?

A: Each unit includes two copper/brass rings, two steel balls, a heat-resistant glass beaker, a ball positioning guide, a ring holder, a support assembly, ball centering guides, and a thermometer holder (thermometer not included).

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Physics Lab Instruments Category

Conversion Of Galvano Meter Into Ammeter

Conversion Of Galvano Meter Into Ammeter

Price 3750 INR / Piece

Minimum Order Quantity : 1 Piece

Capacity : 05 Amp

Temperature Range : 0C to 50C

Usage : Physics Laboratory, Demonstration of converting Galvanometer to Ammeter

Equipment Materials : Acrylic Base, Copper Wire, Galvanometer, Resistor

Galvanometer (MO-65)

Galvanometer (MO-65)

Price 450 INR / Piece

Minimum Order Quantity : 1 Piece

Capacity : 1 Kg/hr

Temperature Range : 1040 0C Celsius (oC)

Usage : For Laboratory

Equipment Materials : Iron & Bakelite

Operational Amplifier as Inverting & Non-Inverting

Operational Amplifier as Inverting & Non-Inverting

Price 5550 INR / Piece

Minimum Order Quantity : 1 Piece

Capacity : 1 Kg/hr

Temperature Range : 1040 0C Celsius (oC)

Usage : For Laboratory

Equipment Materials : Iron & Bakelite

Bi Metallic Strip

Bi Metallic Strip

Price 210 INR / Piece

Minimum Order Quantity : 1 Piece

Capacity : Up to 10 A

Temperature Range : 40C to +150C

Usage : Thermal Sensitive Switching, Circuit Breakers, Thermostats

Equipment Materials : Brass and Nickel Iron Alloy