TRIODE VALVE CHARACTERISTICS APPARATUS Specification

  • Measurement Range
  • Plate current: 050 mA; Grid voltage: -2 V to -50 V
  • Color
  • WHITE
  • Accuracy
  • 2% of scale
  • Capacity
  • Designed for lab scale testing and student experiments
  • Frequency
  • 50 Hz
  • Material
  • IRON
  • Temperature Range
  • Ambient to 50C
  • Core Components
  • Rectifier unit, resistive load, analog voltmeter/ammeter, triode valve socket
  • Voltage
  • Variable up to 250 V DC output
  • Feature
  • Direct measurement of plate and grid characteristics
  • Model No
  • TVA-01
  • Automation Grade
  • Manual
  • Power Source
  • 230 V AC mains
  • Equipment Materials
  • Iron chassis, Bakelite knobs, polycarbonate panel
  • Type
  • ANALOG
  • Usage
  • Electrical/Electronics Laboratory, Student Experimentation
  • Display Type
  • Analog meters
  • Dimension (L*W*H)
  • Approx. 45 x 25 x 20 cm
  • Weight
  • Approx. 8 kg
  • Input Ports
  • External grid voltage input port
  • Cooling System
  • Ventilated base to dissipate heat
  • Panel Meter Type
  • High-contrast analog dial
  • Output Terminals
  • Isolated banana sockets for safe measurement
  • Fuse Protection
  • Built-in fuse for overload protection
  • Lamp Holder Socket
  • Standard Triode Valve compatible
  • Safety Feature
  • Shock-proof construction and insulated wiring
  • Finish Type
  • Powder coated for durability
 

TRIODE VALVE CHARACTERISTICS APPARATUS Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Main Domestic Market
  • All India
 

About TRIODE VALVE CHARACTERISTICS APPARATUS



Experience a triumphant fusion of precision and safety with the TRIODE VALVE CHARACTERISTICS APPARATUS. This hot deal offers a standard triode valve-compatible lamp holder and highly remarked, isolated banana sockets for secure measurement. Boasting a lustrous, powder-coated iron chassis with a ventilated base, the apparatus ensures durability and reliable cooling. Key features include shock-proof, insulated wiring, a high-contrast analog dial, and a robust fuse for overload protection. Designed for laboratory demonstrations or student experimentation, this manual model assures best price performance for direct measurement of triode plate and grid characteristics. Suitable for exporters, manufacturers, and suppliers across India.

Versatility, Application & Material Features

The TRIODE VALVE CHARACTERISTICS APPARATUS is highly suitable for use in electrical and electronics laboratories, facilitating both instruction and research-level experimentation. With durable materials such as iron, Bakelite knobs, and a polycarbonate panel, it is engineered for longevity and repeated handling. Widely highlighted for its direct measurement convenience, its insulated and shock-proof construction ensures safe student use, while the ventilated base effectively dissipates heat in plant or institutional settings.


Payment Terms, Certifications, and Export Markets

Outlay for the TRIODE VALVE CHARACTERISTICS APPARATUS ensures exceptional value, with competitive pricing and reliable transportation methods for global shipment. The apparatus adheres to deep-rooted quality standards, making it a remarked choice for buyers seeking certifications. This triumphant product finds its main export markets across educational and research institutions worldwide, minimizing expenditure while maximizing dependable performance for distributors and end-users alike.


FAQ's of TRIODE VALVE CHARACTERISTICS APPARATUS:


Q: How can the TRIODE VALVE CHARACTERISTICS APPARATUS enhance laboratory experiments?

A: The apparatus allows direct measurement of plate and grid characteristics, offering hands-on experience and accurate results, which are essential for comprehensive learning in any electrical or electronics laboratory.

Q: What safety measures are incorporated in this apparatus?

A: It features shock-proof construction, insulated wiring, a built-in fuse for overload protection, and isolated banana sockets to ensure safe operation during experiments.

Q: When is the ideal time to use this apparatus in an academic setting?

A: It is best used during instructional lab sessions, practical examinations, or student projects requiring an understanding of triode valve behavior and characteristics.

Q: Where can the TRIODE VALVE CHARACTERISTICS APPARATUS be installed?

A: The apparatus is designed for easy installation on laboratory workbenches in educational institutions, research facilities, and plant training centers.

Q: What is the process for measuring plate and grid characteristics with this equipment?

A: Simply connect the triode valve to the compatible lamp holder, use the high-contrast analog meters to read values, and safely adjust inputs via ventilated and shock-proof controls for accurate data collection.

Q: What benefit does the apparatus' powder-coated iron chassis provide?

A: The powder-coated finish offers remarkable resilience against corrosion and wear, ensuring a lustrous and enduring appearance even after repeated use.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Physics Lab Instruments Category

Four Stroke Engine Demonstration Model

Four Stroke Engine Demonstration Model

Price 8700.0 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Laboratory Demonstration, Training

Weight : 2 kg Kilograms (kg)

Temperature Range : Ambient to 60 C Celsius (oC)

Display Type : Analog

Hydrostatic Balance

Hydrostatic Balance

Price 1000 INR / Unit

Minimum Order Quantity : 1 Unit

Usage : Laboratory

Weight : 700 900 Kilograms (kg)

Temperature Range : 15C 40C

Display Type : Analog

STEFAN'S CONSTANT CHARACTERISTICS APPAARTUS

STEFAN'S CONSTANT CHARACTERISTICS APPAARTUS

Price 3800 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Determining StefanBoltzmann Constant

Weight : Approx 5 kg

Temperature Range : Room Temperature to 250C

Display Type : Analog

PLANKS CONSTANT APPARATUS

PLANKS CONSTANT APPARATUS

Price 18500 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Measurement and determination of Plancks constant

Weight : Approx. 2.5 kg

Temperature Range : Operating in standard lab environments

Display Type : Analog and Digital options